|
Build Your Online Product Catalogs?
Product Name: |
Low-voltage electric panel for factory/hotel/resident
|
Supply Ability: |
1000 units |
Related proudcts |
electric panel, |
Specifications |
various models of electrical panel available |
Price Term: |
FOB,CNF,CIF |
Port of loading: |
Qingdao |
Minimum Order |
1unit |
Unit Price: |
500-5000USD |
|
electric panel 1.IEC60439,GB7251 3.IP30/40 switchgear Movable Switchgear, Switching Device, Protective Box Standards GB7251.1 Low-voltage switchgear assemblies IEC60439 Low-voltage switchgear and controlgear assemblies Service condition 1. Ambient temperature: -5'C~+40'C. Average temperature in 24 hours <= 35'C. 2. Altitude: <=2000m. 3. Air humidity at 40'C <=50%. Higher humidity at lower temperature is permitted. Occasional condensation due to temperature variation should be considered. 4. No excessive vibration. 5. No corrosion to electric elements. Special condition subject to users. Electric switchgear panel Features and Benefits 1.SICO MNS switchgear assembles 4, 2 or 1 drawer units in the ***ce of 8E height, or 1 unit in 16E or 24E. SICO GCS switchgear drawers are divided into 1/2, 1, 2, 3 units 2.Breaker co***rtment doors have no ventilation openings, thus protecting operators from hot ionized gases vented by the breaker during circuit interruption. 3.A superior bus system offers different levels of protection. Insulated and isolated bus makes maintenance procedures touch friendly to reduce the risk of arc flash. 4.True closed-door drawout construction is standard with all SICO GCS, SICO MNS equipment. The breaker co***rtment doors remain stationary and closed while the breaker is racked out from the connect position, through test, to the disconnect position. Doors are secured with rugged 1/4-turn latches. 5.An easy-to-read metal instrument panel above each circuit breaker holds a variety of control circuit devices, including the RELT switch. 6.Each circuit breaker is located in a completely enclosed ventilated co***rtment with grounded steel barriers to minimize the possibility of fault communication between co***rtments. 7.Optional safety shutters protect operators from accidental contact with live conductors when the breaker is withdrawn. 8.Easy access to equipment co***rtments simplifies maintenance of the breaker cubicle and control circuit elements as well as inspecti |
Company: |
Qingdao Sico Electronics Co., Ltd.
|
Contact: |
Ms. Yaping Li |
Address: |
Room 2004£¬ Block B Huarun Building£¬N |
Postcode: |
266000 |
Tel: |
8653283025965 |
Fax: |
8653283028251 |
E-mail: |
|
|
|
|