|
Build Your Online Product Catalogs?
Product Name: |
SICO MLS 11kv switchgear for residential building/hotel/factory
|
Supply Ability: |
1000 units |
Related proudcts |
switchgear, |
Specifications |
MNS/GGD/GCK/GCS switchgear |
Price Term: |
FOB,CNF,CIF |
Port of loading: |
Qingdao |
Minimum Order |
1unit |
Unit Price: |
500-5000USD |
|
SICO MLS 11kv switchgear for residential building/hotel/factory power distribution a) 11kv switchgear Main circuit: AC 220V, 380V, DC 220V; b) 11kv switchgear auxiliary circuit: AC 220V, 380V, DC 220V; SICO MLS 11kv switchgear for residential building/hotel/factory power distribution
11kv switchgear Production Description SICO MLS 11kv switchgear for the exchange of 50-60Hz rated voltage 660V and below power supply system, power plants, substations, building hotels, airport terminals, etc., as distribution, electric motors and electric equipment, control, lighting, power conversion, power compensation purposes. The 11kv switchgear structures of a highly flexible use different standard components that can maximize the fault arc to prevent the occurrence of extinction in a short time, small size, convenient installation and maintenance. 11kv switchgear Voltage 11kv switchgear Rated working voltage (Ue) a) Main circuit: AC 220V, 380V, DC 220V; b) auxiliary circuit: AC 220V, 380V, DC 220V; Note: Users of the auxiliary circuit have special requirements, should be resolved through consultation with the manufacturer 11kv switchgear Rated insulation voltage The main circuit rated insulation voltage 660V. 11kv switchgear Rated Current a) the level of bus (main busbar) Rated current: 2000,2500,3200,4000 A, 5000A; b) Vertical Bus (branch busbar) Rated current: 1000A. 11kv switchgear Rated short-time withstand current (1s) a) the level of bus (main bus): 80KA; b) Vertical Bus (branch bus): 50KA; c) Protection of conductors (grounding the main bus): 50KA; d) neutral bus (neutral main bus): 50KA. 11kv switchgear Rated peak withstand current a) the level of bus (main bus): 176KA; b) Vertical Bus (branch bus): 105KA; c) Protection of conductors (grounding the main bus): 100KA; d) neutral bus (neutral main bus): 100KA. 11kv switchgear functional unit the main circuit breaker or fuse breaking capacity a) by the power unit is: 80KA; b) feed modules: 50KA. 11kv switch |
Company: |
Qingdao Sico Electronics Co., Ltd.
|
Contact: |
Ms. Yaping Li |
Address: |
Room 2004£¬ Block B Huarun Building£¬N |
Postcode: |
266000 |
Tel: |
8653283025965 |
Fax: |
8653283028251 |
E-mail: |
|
|
|
|